Product Description

Fungilab Quality + low cost= Viscolead Serie

Viscolead Adv

Measuring of advanced viscosity. Easy to use. 2 years of garantee

Main Features

Screen Data
Selected speed rpm
Selected spindle SP
Viscosity reading cP (mPa·s) or cSt
Percentatge of full scale %
Sampling temperature ºC or ºF
Shear Rate (with coaxial spindles) SR (s-1)
Shear Stress (with coaxial spindles) SS (N/m2)
Density (introduced by the user) g/cm3
Viscosity reading
Dynamic viscosity cP or mPa·s
Kinematic viscosity cSt
Units Converter from SI to CGS
​Program features
Time to torque: Ending of the test upon reaching a programmed torque
Time to stop: Ending of the test upon reaching a programmed time
10 working memories
Other main features
AUTO-TEST with visual and resonant alarm
AUTO-RANGE function
Temperature Reading through PT100 probe
User-enabled viscosity and temperature calibration
10 language options
Port: USB
Software Datalogger: USB lets tranfer data to an Excel file in the PC

Spindles

AISI 316 Stainless steel spindle, easily to identify according to its letter and number, in terms of the range of viscosity. Our units fulfills the next standards: These are the standards our units follow: BS: 6075, 5350
  • BS: 6075, 5350
  • ISO:2555,1652
  • ASTM: 115, 789, 1076, 1084, 1286, 1417, 1439, 1638, 1824, 2196, 2336, 2364, 2393, 2556, 2669, 2849, 2983, 2994, 3232, 3236, 3716

Standard delivery

  • The equipement is supplied complete with standard spindles
    • 4 spindles for L model
    • 6 spindles for R and H models
  • Viscometer stand
  • Spindle protector
  • Temperature probe PT100
  • Carring case
  • USB cable
  • Datalogger software
​Technical specifications
Precision: +/- 1% full scale of range
Resolution: For a minus viscosity of 10.000 cP : 0.1 cP For a major viscosity of 10.000 cP : 1 cP With the low viscosity adapter (LCP-LCP/B) : 0.01cP
Repeatability: 0.2%
Temperature probe features: Temperature limits: -10ºC to 150ºC 14ºF to 302ºF Resolution: 0.1ºC / -17.722 ºF Precision: +/- 0.2ºC / +/- 17.666 ºF Type of probe: PT100
Supplied at 110-240VAC, 50/60 Hz.
Accessories
APM Small Sample Adapter with circulation jacket (without TL or TR spindles) Sample volume (6.7 - 13 ml.) Compatible with Brookfield viscometers
APM/B Small Sample Adapter without circulation jacket (without TL or TR spindles) Sample volume (6.7 - 13 ml.) Compatible with Brookfield viscometers
LCP Low Viscosity Adapter with circulation jacket (with spindle) Sample volume (16 ml.) Compatible with Brookfield viscometers
LCP/B Low Viscosity Adapter without circulation jacket (with spindle) Sample volume (16 ml.) Compatible with Brookfield viscometers
HELDAL Helix Drive Unit Accessory for measuring non-flowing substances viscosity (with spindles)
THERMOSPHERE Temperature control unit up to 300 ºC
Code Model Measuring Range (cP) Speed (r.p.m) Number of speeds
VL210003 ADV L *1 - 2.000.000 0.3 - 100 18
VL210002 ADV R 100 - 13.000.000 0.3 - 100 18
VL210001 ADV H 200 - 106.000.000 0.3 - 100 18
The viscosity range of the equipment is referenced between 0.01 and 100 rpm.
PPRFast spindle switch (push plug and release)
Code Model Measuring Range (cP) Speed (r.p.m) Number of speeds
VL211003* ADV L + PPR *1 - 2.000.000 0.3 - 100 18
VL211002* ADV R + PPR 25 - 13.000.000 0.3 - 100 18
VL211001* ADV H + PPR 200 - 106.000.000 0.3 - 100 18
The viscosity range of the equipment is referenced between 0.01 and 100 rpm.

Ranges

  • (L) Low viscosity model
  • (M) Medium viscosity model
  • (H) High viscosity model
Low viscosity: The minimum viscosity when using a "L" range with standard spindles is 10 cP * For measurements < 10cP, its recommended to use in conunction with the low viscosity adapter (LCP or LCP/B)

VISCOLEAD ADV

Card image cap
DATALOGGER
PROGRAM FEATURES
SPEED RANGE 0,3 - 100 rpm
Nº SPEEDS 18
VISC. RANGE 1 - 106M
TEMPERATURE PROBE

VISCOLEAD ONE

Card image cap
DATALOGGER
PROGRAM FEATURES
0,3 - 100 rpm SPEED RANGE
18 Nº SPEEDS
1 - 106M VISC. RANGE
TEMPERATURE PROBE

Product Features

Data displayed

Selected Speed, Selected Spindle, Viscosity readings (cP or mPa·s or cSt), Percentage of Full Scale Range (%), Sample Temperature (ºC or ºF), Shear rate (with coaxial spindles) (s-1), Shear Stress (with coaxial spindles) (N/m2), Density (introduced by the user) (g/cm3)

Temperature reading by PT100

Included on standard delivery

Languages options

English / French / German / Catalan / Spanish / Italian / Japanese / Polish / Dutch / Portuguese

suitability

Program features

Time to torque, time to stop, Unit Converter (IS or CGS).

USB interface

Faster transfer data to the computer

10 Working memories

Set up the unit and get it ready to be used every day choosing the memory you need

Viscosity readings

Absolute viscosity (cP or mPa·s) working with accessories, Apparent viscosity (cP or mPa·s), Kinematic viscosity (cSt, mm2/sec), (Density introduced by the user)

Datalogger software included

USB allows data transfer to a Excel format

AUTO-TEST

It checks the internal function in order to make the unit ready to use

Customer reviews

0
0 ratings
1 Star
0%
2 Star
0%
3 Star
0%
4 Star
0%
5 Star
0%
Reviews

There are no reviews yet.

Be the first to review “ADV”