PRODUCTS
V-Pad viscometers
+ infoDynamic viscosity measurement for laboratory and industrial applications
Dynamic viscosity measurement is essential for evaluating how liquids and semi-solid materials resist flow under applied force. Accurate viscosity data supports product development, quality control and process optimisation across a wide range of industries.
Fungilab provides complete dynamic viscosity measurement solutions based on precision rotational viscometers, temperature control systems and specialized accessories designed to deliver reliable, repeatable and traceable laboratory results.
Whether measuring low-viscosity liquids or highly viscous materials, Fungilab offers instruments adapted to routine laboratory testing as well as demanding research applications.
Our products
Viscolead Series
Viscolead ONE
Viscolead ADV
Accessories
LABORATORY DIVISION
Dynamic viscosity
Viscosity is part of the science of Rheology which quantifies the resistance materials give to changing shape.
Proper interpretation of viscosity data can reduce the rate of rejects while keeping production and formulation development costs to a minimum. Consistent product quality is ensured through proper viscosity measurements, either alone or in conjunction with compatible tests.
Dynamic viscosity testing can help with:
- Material characterization or “finger-printing”
- Standard testing methods to check for differences between batches
- Indirect way of measuring quality
- Product formulation
- Quality control
- Process control
- Design, optimization and operation of process equipment
Material characterization or “finger-printing”
Standard testing methods to check for differences between batches
Indirect way of measuring quality
Product formulation
Quality control
Process control
Design, optimization and operation of process equipment
Viscosity types
Dynamic viscosity
Centipoise (mPa*s)
Kinematic viscosity
Centistokes (mm2/sec)
Apparent viscosity
Centipoise (mPa*s)
Newton’s Law
According to Newton’s law, the viscosity of a fluid is constant. As shear rate changes, shear stress changes in proportion such that viscosity is constant. Common fluids that exhibit such behavior are:
Unfortunately for us, not all fluids follow Newton’s law. In fact, most fluids do not. For this reason, fluids are classified into two categories:
Rotational Viscometer
The viscosity is calculated from the measured torque and rotational speed, as well as the dimensions of the measuring geometry.
A fluid’s resistance to flow is measured by the torque it exerts on the rotating shaft of the viscometer.
Absolute viscosity: the measuring geometry fulfills certain requirements (which is the case of coaxial spindles).
Relative viscosity: the dimensions of the measuring geometry are not well defined.
Advantage
Flexibility in:
- Viscosity Range
- Temperature range
- Shear rate range
Application
For Newtonian and non-Newtonian substances and temperatures different from room temperature.
Professional touchscreen rotational viscometers for laboratory applications
V-Pad viscometers determine dynamic viscosity by measuring the torque generated while a spindle rotates at a controlled speed inside the sample. Their touchscreen interface and programmable measurement functions allow laboratories to perform repeatable viscosity testing while improving workflow efficiency.
Available in multiple measuring ranges, V-Pad instruments can be configured to analyse a wide variety of liquid and semi-solid materials using interchangeable measuring systems and optional accessories. :contentReference[oaicite:1]{index=1}
Typical applications
- Pharmaceutical products.
- Cosmetics and personal care.
- Food and beverages.
- Paints and coatings.
- Adhesives and sealants.
- Chemical products.
- Petroleum and lubricants.
- Research and development laboratories.
Advanced measurement capabilities
V-Pad viscometers incorporate programmable testing functions that support advanced viscosity studies, including customised methods and automated measurement sequences. Wireless communication and touchscreen operation improve usability while maintaining high measurement accuracy. :contentReference[oaicite:2]{index=2}
Specialized accessories
Fungilab offers a complete range of accessories to expand the measurement capabilities of V-Pad viscometers.
- Small Sample Adapter (APM) for limited sample volumes.
- Low Viscosity Adapter (LCP) for low-viscosity liquids.
- HELDAL Unit for highly viscous and non-flowing materials.
- Thermosphere for elevated-temperature viscosity testing.
Temperature-controlled viscosity measurements
Accurate viscosity determination requires stable sample temperature. Fungilab provides heating circulators and refrigerated circulators to ensure precise thermal regulation during testing.
Calibration and verification
Routine verification using certified viscosity standard oils helps maintain measurement accuracy, repeatability and traceability throughout the lifetime of the instrument.
Benefits of V-Pad viscometers
- Intuitive touchscreen operation.
- High measurement accuracy and repeatability.
- Programmable testing methods.
- Wireless communication capabilities.
- Wide accessory compatibility.
- Suitable for routine quality control and advanced laboratory research.
Frequently asked questions about the Viscolead ADV
What is a V-Pad viscometer?
A V-Pad viscometer is a professional rotational viscometer featuring a touchscreen interface for accurate dynamic viscosity measurements in laboratory and quality control applications.
Which materials can be measured?
V-Pad viscometers are suitable for liquids, oils, creams, gels, coatings, adhesives and many other Newtonian and non-Newtonian materials.
What are the advantages of the touchscreen interface?
The touchscreen simplifies instrument operation, method selection, parameter configuration and data management during viscosity testing.
Can V-Pad viscometers be used with different accessories?
Yes. They are compatible with accessories such as the Small Sample Adapter, Low Viscosity Adapter, HELDAL Unit and Thermosphere system.
Why is temperature control important?
Since viscosity changes with temperature, stable thermal conditions are essential for obtaining accurate and repeatable measurement results.
How is measurement accuracy maintained?
Routine verification with certified viscosity standard oils helps ensure reliable and traceable viscosity measurements.
Which industries use V-Pad viscometers?
They are widely used in pharmaceutical, cosmetic, food, chemical, coating, lubricant and research laboratories.
What are the main benefits of V-Pad viscometers?
They combine high measurement precision, programmable testing, touchscreen operation, wireless functionality and excellent versatility for modern viscosity laboratories.